To replace the double delta seals on the pistons, do the following:
- Remove the backing plate. Refer to Removing and Installing the Backing Plate for more information.
- If equipped, remove the center plate. Refer to the ultra valve gate hot runner manual (If Equipped) for more information.
- Remove the valve stem assemblies. Refer to Removing and Installing Valve Stems for more information.
- For each valve stem assembly that requires new double delta seals, do the following:
- Install the valve stem assemblies. Refer to Removing and Installing Valve Stems for more information.
- If equipped, install the center plate. Refer to the Ultra Valve Gate Hot Runner Manual for more information.
- Install the backing plate. Refer to Removing and Installing the Backing Plate for more information.